::::::::::
:: Site Map
: :     OmniBus VME ARINC 717    Home > Products > ARINC 717 > OmniBus VME ARINC 717
 

OmniBus VME™ Interface for ARINC 717

  • Up to 32 ARINC 717 channels
  • Software-selectable biphase/bipolar channels
  • Variable transmit amplitude
  • Eight ARINC 717 speeds, from 64 to 8192 words/sec
  • Mix with ARINC 429/708, MIL-STD-1553, serial ports, CSDB, and/or discrete IO on the same board
  • PowerPC® user processor
  • Ethernet and serial ports
  • On-board CompactFlash®
  • PMC site available
  • IRIG time synchronization
  • Extended temperature available
  • Can be upgraded/reconfigured
OmniBus VME Interface for ARINC 717
OmniBus VME

Description


The high-performance OmniBus VME may be used for simulating, monitoring, and testing up to 16 ARINC 708 channels or a combination of ARINC 708 with other protocols. OmniBus VME is a member of Ballard's OmniBus® product line, a family of avionics databus interfaces that takes flexibility and power to a new level. With the demand for products with high channel counts and multi-protocol capability comes the need for more processing power, not only for handling the protocol but also for running the user's application. The OmniBus Family has addressed these requirements through modularity and by adding multiple processors.



TOP OF PAGE

ARINC 717 channels


OmniBus ARINC 717 channels can be configured by the user as biphase or bipolar and the amplitude of transmit channels can be configured by the user. ARINC 717 channels are capable of operating at 64, 128, 256, 512, 1024, 2048, 4096, and 8192 wps. OmniBus ARINC 717 modules can include ARINC 429 channels, allowing the user to communicate over 717 databuses while simultaneously transmitting and receiving ARINC 429 data. This configuration is ideal for troubleshooting Flight Data Recorders or testing systems that involve the interaction of 429 and 717. Please note that ARINC 429 is also available separately on OmniBus boards for ARINC 429 (see OmniBus Family page).

The OmniBus 717 page contains complete information on ARINC 717/573 functionality for OmniBus products.

ARINC 717 channels can be mixed with other protocols. See the OmniBus VME Configurations section below for examples.



TOP OF PAGE

flexible configuration


Through modularity, Ballard can provide unique, user-specified configurations on short notice at minimum cost. The flexibility of this design allows more protocol and channel count configurations to be developed and stocked than is practical with fixed configurations. The unique OmniBus architecture offers higher performance than general-purpose modular systems. Modularity also means that user may upgrade or reconfigure their OmniBus with additional functionality, channels, and protocols as their requirements change.



TOP OF PAGE

multiple processors


OmniBus modularity allows additional processors to be added as more channels and/or protocols are added. Because each module has its own DSP (see diagram below), OmniBus products provide high channel count and mixed protocol capability without relying on the host processor or risking data loss from an overloaded DSP. By including more channels, protocols, and processing power in a single product, OmniBus provides better economy of scale and requires less computer space (slots).

OmniBus VME Architecture



TOP OF PAGE

user processor


An on-board PowerPC processor can be programmed by the user to off-load or run independently of the VME system processor. Users can upload programs and may save them in non-volatile on-board memory. The PowerPC can be configured to automatically boot and run without host intervention. OmniBus VME can function as a VME system controller or as an intelligent I/O board. Possible applications include data servers/converters, dynamic data generation/simulation, data filtering, and event triggering.



TOP OF PAGE

additional capabilities


  • OmniBus VME provides a 10/100 Ethernet port, two serial RS-232 ports, and CompactFlash® socket.
  • In addition to normal operation through the VME backplane, the OmniBus VME may be controlled remotely through the Ethernet port.
  • The VME interface is implemented with the Universe II from Tundra, which provides a wide range of address and data transfer modes.
  • For additional flexibility, OmniBus VME can be ordered with a PrPMC-compatible PMC site that can operate in Monarch or non-Monarch modes.
  • IRIG circuits allow channels, boards, and other equipment to be synchronized to a standard clock time. The IRIG time can come from an outside source or be generated on board.
  • All OmniBus modules include various digital input and output signals.



TOP OF PAGE

OmniBus VME Configurations


Module Count per Board
 Model Modules PMC
 152 21
 154 40

Channel Count per Module
 Protocol Maximum Channels
 1553 2 (both dual-redundant)
 429 16 (various R/T configurations)
 708 4 (2R/2T)
 717 Mix (biphase and bipolar)
 Serial 4 UART Ports
 CSDB 8 (4R/4T w/ parametrics)

Example Configurations for 2 Modules

  • Up to 8 ARINC 717 channels plus up to 24 ARINC 429 channels
  • Up to 8 ARINC 717 channels plus up to 8 ARINC 429 channels and 2 or 4 ARINC 708 channels
  • Up to 4 MIL-STD-1553 channels
  • Up to 32 ARINC 429 channels
  • 1 or 2 MIL-STD-1553 channels plus up to 16 ARINC 429 channels
  • Up to 16 ARINC 429 channels plus 2 or 4 ARINC 708 channels
Example Configurations for 4 Modules
  • Up to 16 ARINC 717 channels plus up to 48 ARINC 429 channels
  • Up to 16 ARINC 717 channels plus up to 16 ARINC 429 channels and 4 or 8 708 channels
  • Up to 8 MIL-STD-1553 channels
  • Up to 64 ARINC 429 channels
  • 1 or 2 MIL-STD-1553 channels plus up to 48 ARINC 429 channels
  • Up to 48 ARINC 429 channels plus 2 or 4 ARINC 708 channels



TOP OF PAGE

Technical Specifications


Physical

  • 6U x 4HP (233 x 160 x 20 mm)
  • Convection cooling
  • 0° to +55° C (standard); extended temperatures available

Interface

  • IBM 405GPr processor
  • Tundra Universe II VME interface
    • A32/A24/A16 master and slave
    • D64/D32/D16/D08 master and slave
    • MBLT, BLT, ADOH, RMW, LOCK, location monitors
  • OmniBus module sites: 2 or 4
  • PMC site (model 152 only)
    • PrPMC-compatible
    • Monarch or non-Monarch modes
  • Ethernet 10/100
  • RS-232 serial: two ports (on single RJ11/RJ12)
  • CompactFlash socket
  • IRIG modes A and B 



TOP OF PAGE

software


Software developers can use the Application Program Interface (API) to quickly develop an application. Although each OmniBus product can be easily configured and run with only a few API calls, the comprehensive library includes a broad range of functions for specialized needs. All OmniBus products run Ballard's universal BTIDriver™ API, so applications developed for one platform or product can be easily ported to another.

Windows® 2000/XP drivers are included as well as source-level drivers for interfacing to the OmniBus VME board. A software development kit (SDK) is available to implement applications for the on-board PowerPC processor.



TOP OF PAGE

Ordering Information


The OmniBus VME card can be ordered in many combinations of modules and features. The complete order number for an OmniBus VME card is a combination of the main model number, module number(s), and options. Ballard Technology also offers a variety of cables and other accessories that interface with our products as well as various databuses. Please contact Ballard Technology for specific ordering information.



TOP OF PAGE

Download Brochure


  Click here to download a PDF version of the OmniBus_717 Product Brochure

Adobe Acrobat is required to view the PDF.
Click here to download a free version of Acrobat Reader

Top

Table of Contents:
Description
ARINC 717 channels
flexible configuration
multiple processors
user processor
additional capabilities
OmniBus VME Configurations
Technical Specifications
software
Ordering Information
Product Brochure

FEATURED PRODUCT
Ethernet/USB for ARINC 717
Ethernet/USB for ARINC 717
  • IRIG Timetag
  • PowerPC user processor
  • CompactFlash slot
  • Software-Selectable

The OmniBusBox enables computers and networks to interface with up to 16 ARINC 717 channels or a combination of ARINC 717 with other protocols via Ethernet or USB.

More...

Related Products:
software
717 Monitor GUI
hardware
OmniBus Ethernet/USB A 717
OmniBus PCI ARINC 717
OmniBus cPCI ARINC 717
OmniBus VME ARINC 717
BUSBox ARINC 717
PCI ARINC 717
cPCI ARINC 717
PCMCIA ARINC 717
Handheld ARINC 717
ARINC 429 Products
other
Cables And Accessories
 

For More Information
Call: 800.829.1553
Email:
Request a quote
:: Copyright © 2008 Ballard Technology, Inc. All rights reserved.:: Login:: Privacy policy:: Legal